CFS-II

Capsule Filter Rod Quality Sorter

Automatic sorter that checks capsule filter rods and rejects defects. Microwave measurement and high-speed precision sensors detect capsule count, position and damage.

← Back to Capsule Testing

Measured Parameters

  • Composite structure & phase
  • Sorting & rejection

Features

  • Beckhoff IPC control with EtherCAT real-time Ethernet for nanosecond-level data acquisition
  • Microwave measurement inspects and rejects at high speed without damaging rods
  • Checks every rod and removes defective ones in real time
  • Distributor receives, buffers, sorts and rejects rods reliably; manual receiving bench provided
  • Feeds directly from filter rod boxes for high efficiency

Technical Specifications

ModelCFS-II
Detection modeContinuous detection, automatic rejection
Applicable samplesStandard and composite capsule filter rods (composite custom)
Rod length range60–150 mm
Rod diameter rangeφ5.4–6.0 / 6.0–7.0 / 7.0–8.0 mm
Capsule diameter≥2 mm
Min. capsule spacing≥4 mm
Min. capsule to end face≥3 mm
Capsule position accuracy±0.2 mm
Hopper capacity2–3 boxes, whole-box feeding
Testing speed≥1500 pcs/min (special rods confirmed on site)
Capsule colorUnlimited
Detection accuracy≥99.99%
False rejection rate≤0.05%

Operating Environment

Ambient humidity40%–65% RH (recommended (60±5)% RH)
Ambient temperature+10 ~ +35 °C (recommended (22±2) °C)
Power supplyAC 220 V ±10%, 50 Hz ±5%
Air supply0.5–0.8 MPa, ≥80 L/min, free of water, oil and dust

Applications

  • Production-floor sampling

Related Equipment

Send an Inquiry

Tell us the products, specifications and quantities you need, and we will reply promptly.